Singapore indoor air quality assessment protocol
Healthy Space protocol

A transparent path to certification.

The attribution process separates the baseline, the intervention and the verified outcome. This helps clients understand what changed and what must be maintained.

Define scope and acceptance criteria

Confirm premises, occupied zones, hours, sensitive users, complaints and relevant benchmarks. Agree the parameters and pass criteria before treatment.

Conduct site review and baseline testing

Record occupancy, temperature, relative humidity, ventilation conditions and likely sources. Sample relevant parameters such as PM2.5, carbon dioxide, total VOCs and formaldehyde.

Design the control plan

Prioritise source removal, ventilation, filtration, moisture correction and maintenance. Specify SmartCoat or another anti-pollutant treatment only where suitable for the identified issue.

Document application

Record product, treated surfaces or equipment, batch details, coverage, application date, contractor and curing or commissioning conditions.

Verify under comparable conditions

Repeat agreed measurements after the stated stabilisation period. Compare conditions, methods and results against the baseline and acceptance criteria.

Attribute and issue

Review the full evidence chain. If the criteria are met, issue a unique certificate with scope, result date, limitations and recommended reassessment date, then publish its registry record.

What is checked

The final test plan is risk-based. It avoids claiming causation where operating conditions or multiple interventions prevent a clean comparison.

Assessment evidence

  • Calibrated or fit-for-purpose instruments
  • Named sampling zones and time windows
  • Indoor and relevant outdoor conditions
  • Occupancy and HVAC operating state
  • Before and after results

Certificate record

  • Unique certificate number
  • Premises and assessed scope
  • Protocol version and criteria
  • Issue and review dates
  • Status and material limitations
Decision logic

How attribution works

VERIFIED

Criteria met

The post-treatment results meet the agreed criteria, with an adequate and traceable evidence record.

CONDITIONAL

Further action needed

Results improve but a control, operating condition or parameter needs correction before certification.

NOT ATTRIBUTED

Causation unclear

Results may be recorded, but the change cannot reasonably be linked to a specific treatment or control.

Certification reflects sampled conditions and the stated scope at a point in time. It does not guarantee that a space is free of every pollutant, pathogen or future air-quality risk.

☎